Gynaecology Instrument working principle

1 gynecological comprehensive treatment instrument First, the working principle; through the light composite effect, effectively kill the diseased tissue, so that the pathological changes in tissue protein coagulation, degeneration, necrosis, vascular coagulation occlusion, while improving normal tissue cell proliferation, as a substitute for lesion tissue Series of benign reactions, to achieve the purpose of cure. Which is characterized by short treatment time, the treatment of I, II, III degree of cervical erosion every time interval of only 3-5 seconds; patients with less pain, high efficacy, smokeless and tasteless, healed without scars, smooth surface, recovery elasticity. Second, the scope of application: gynecological comprehensive treatment instrument is a common treatment for gynecological inflammation and certain skin diseases, a comprehensive treatment. The treatment instrument is characterized by a therapeutic instrument can be achieved on three different treatment functions, namely: treatment therapy, infrared light treatment and high frequency electrocautery treatment. 

Third, the infrared light gun operation steps (1) adjust the infrared light, therapy lamp and electrocautery switch, turn it to the "infrared light" Department. (2) Insert the infrared light gun connection plug into the panel "Infrared light output". (3) Turn on the "main power switch" to turn on the main unit, the power switch indicator light, fan rotation, "power time" display "0000,0000". (4) power adjustment: press the power adjustment up arrow keys, transferred to the treatment of the required power. (5) Open the treatment head handle switch, that is, step (4) set the power output, the time shown as the timing of the state. (6) in the course of treatment, turn off the handle switch, then stop the time, open the switch again, continue to time. (7) At the same time press the power to adjust the up and down arrows, the display time is cleared and re-counted. (8) after the end of treatment, turn off the handle switch, and then continue to let the fan turn a few minutes before turning off the total power. Contraindications 1, infrared light treatment has the following contraindications: (1) suffering from severe heart, liver, kidney dysfunction disabled. (2) patients with hemorrhagic disease, acute reproductive system infection, fever and other symptoms disabled. (3) suffering from acute vaginitis, acute cervicitis, acute pelvic inflammatory disease and other symptoms of patients, need to be cured after inflammation to use infrared light. (4) patients with poor blood coagulation are advised not to use infrared light irradiation. 2, high-frequency electrocautery treatment has the following contraindications: high fever patients, active tuberculosis, severe arteriosclerosis, compensatory heart disease and in vivo implanted pacemaker patients. Note: 1, infrared light gun: (1) irradiation guns can not direct exposure to the eye. (2) irradiation gun treatment head is damaged objects, so be sure to be careful, not with other objects touch. (3) When wiping the probe with alcohol, make the treatment head vertical, the probe head down. (4) The reflector and the light source assembly of the irradiation gun are optically adjusted with respect to the treatment head, so do not open the treatment head head cover at will. (5) the end of treatment or place the irradiation gun should be closed to stop the output or turn off the power. (6) Do not place the gun on flammable. (7) operation, in order to protect the eyes, it is recommended to bring a protective mirror. (8) treatment, you should first set the power and time, press the start button, the doctor hand treatment treatment head handle alignment target, according to the manual handle of the work switch irradiation treatment, to avoid exposure to non-treatment site. four. Physiotherapy lamp operation steps

1) Adjust the infrared light, the therapy lamp and the electrocautery switch, and turn it to the "therapy lamp" (2) Insert the therapy lamp connection plug into the panel "Physiotherapy lamp output". (3) Turn on the main power switch, turn on the main unit power, turn on the switch indicator light, "power time" shows "0000,0000". (4) power adjustment: press the power adjustment up arrow keys, transferred to the treatment of the required power. (5) Open the treatment head handle switch, that is, step (4) set the power output, the time shown as the timing of the state. (6) in the course of treatment, turn off the handle switch, then stop the time, open the switch again, continue to time. (7) At the same time press the power to adjust the up and down arrows, the display time is cleared and re-counted.