Polymer Ligation Clips Precautions
Jun 20, 2017

Polymer Ligation Clips Precautions

Product design, testing and production for patients only one-time use. The secondary use or reprocessing of the product will result in damage to the device or damage to the patient. Re-processing / secondary sterilization will produce pollution and the risk of infection. Do not re-use, re-processing or secondary disinfection of the product.

The absorbable ligation clip is released through a disposable magazine and is energized by a reusable applicator. Lapro-Clip ™ ligation clamps are made from two polymers: polyglycolic acid and polyglycol carbonate. Polyglycolic acid outer layer folder, the Department of polyglycolic acid in the inner layer of the folder on the slide. Lapro-Clip ™ ligation clip for sterile delivery, unstained. There are two kinds of ligation clip specifications: medium / large and trumpet. When placed in a disposable magazine, each sterile package contains 6 or 2 magazine, each magazine with a ligation clip. The absorption characteristics of polyglycolic acid and polyglycolic carbonic acid have been extensively studied and documented extensively. Both of these polymers are disintegrated in the human body by hydrolysis. Lapro-ClipTM single-type clamps are available in three sizes: Lapro-ClipTM short single-acting clamp length 11cm, instrument rod diameter 10mm, Lapro-ClipTM standard single-type clamp clamp length 26.5cm, instrument lever Diameter 10cm. Lapro-ClipTM long single hair clamp clamp length 33cm, instrument rod diameter 10mm. Standard and long Lapro-ClipTM single hair ligation clips can be used with a 10mm puncture sleeve or through a transducer with a larger sleeve. The Lapro-Clip ™ ligation clip is placed in a disposable magazine during sale and is activated by a reusable clamp.

Indications Lapro-Clip ™ ligation clip for absorbable ligation. The Lapro-Clip ™ ligation clip has radiopaque and does not affect postoperative x-ray, CT or MRI scans. Lapro-ClipTM ligation clip for cyst artery and bile duct ligation and other common ligation.

Use taboo 1. Lapro-Clip ™ ligation clip is not suitable for sites requiring long or permanent ligation of the tissue or vessel. 2. The device is not suitable for contraceptive ligation of the fallopian tube, but can be used for hemostasis after the fallopian tube.

Precautions and warnings 1. Lapro-ClipTM section re-use clamp clamp for non-sterile supply, so before use must be cleaned and sterilized. 2. Since any damage is likely to affect the safety of the operation of the device, before and after use, you must carefully check the Lapro-ClipTM reusable clamp clamp. Failure to lubricate the device prior to sterilization will result in equipment failure, such as clogging, difficulty in handling or poor closing (if used). The function of the moving parts should be evaluated before use. If the product is damaged, contact your local representative for replacement or repair by the manufacturer.